UV-Vis · NIR · OCT · Raman spectrometers
Spectrometers built for
thermal stability.
Evolve Sensing designs its spectrometers for thermal and mechanical stability first, so wavelength calibration holds over temperature and time. Instruments are available as OEM modules and laboratory units from 155 to 2500 nm.
- <0.04nm/°C wavelength drift
- ±0.05nm reproducibility
- 155–2500nm wavelength coverage
Values are taken from the product datasheets. How thermal drift is measured →
Applications
Spectrometers by application
Evolve Sensing supports measurements in semiconductor, biomedical, pharmaceutical, environmental and industrial settings. Each application page covers the measurement, the specifications that determine instrument choice, and the recommended platforms.
Semiconductor
Plasma & thin film
OES endpoint detection, thin-film thickness, optical CD, deep-UV source monitoring and contamination screening.
View application →Biomedical
Tissue & imaging
OCT, endoscopy, fluorescence, blood parameters and radiation dosimetry.
View application →Pharmaceutical
Process analytics
Dissolution testing, HPLC detection, PAT and cleaning validation.
View application →Environmental
Air, water, waste
DOAS, water quality, emissions, agriculture and food, sorting and recycling, soil chemistry.
View application →Industrial & materials
Raw materials
LIBS on coal and ore, fenceline gas, in-process solids and liquids.
View application →Why Evolve Sensing
Stable optics, drop-in form factors and engineering support
Measured thermal stability
Thermal stability is specified for each model on its datasheet, down to 0.002 nm/°C. SmartEngine, HummingBird and EagleEye reach wavelength reproducibility of ±0.05 nm.
Drop-in form factors
Standard footprints, optical interfaces and USB power allow an end-of-life spectrometer to be replaced without a redesign of the host instrument.
Engineering support
Technical questions are answered by an applications engineer, typically within one business day, before and after the sale.
Spectrometer selector
Search 89 model variants by wavelength range, detector and resolution
All values are drawn from the same specification database used for the product pages and datasheets. Enter the required range and performance, and the list narrows as you type.
| Model | Spectral coverage | Resolution | Detector | SNR | CompareCmp |
|---|
No standard configuration matches that combination. Loosen a filter, or contact an engineer to discuss a custom configuration.
Replacement program
Replacements for discontinued spectrometers
A discontinued spectrometer or a long lead time does not have to stall an instrument program. Send Evolve Sensing the part number in use today, and an engineer will confirm whether an equivalent configuration is available, what would change in the integration, and when a direct equivalent does not exist.
- Matching footprint, optical interface and 5 V USB power
- Documented multi-language SDK
- Evaluation units available before purchase
- Long-term supply and support
Technical library
Measurement notes and application guides
Method notes and diagrams on the physics behind the specifications.
Diagram
Spectral balance in broadband measurements
How intensity roll-off across a broadband source limits a single-bench measurement, and how a dual-spectrometer system addresses it.
Method note
CMOS and CCD detectors compared
Read noise, dynamic range, and the applications where each detector type is the better choice.
Method note
Thermal stability in miniature spectrometers
How wavelength drift with temperature affects calibration, and how to verify a spectrometer's thermal stability in your own setup.
Next step
Discuss your application with an engineer
Send the wavelength range, the sample type and the accuracy required, and an Evolve Sensing applications engineer will recommend a configuration, typically within one business day.