Semiconductor
Plasma & thin film
Semiconductor metrology depends on spectrometers for endpoint detection, thin-film measurement, source monitoring and inspection, and in most of these tasks the limiting specification is stability rather than sensitivity. A spectrometer that drifts between wafer lots degrades endpoint detection and adds error to thin-film thickness results. Evolve Sensing configures UV, visible, NIR and deep-UV spectrometer platforms for OEM tools and process teams in each of these areas.
Typical measurements
Plasma Monitoring and Endpoint Detection
Optical emission spectroscopy on etch and deposition tools, where the useful signal is a small number of emission lines against a bright, changing continuum.
Thin-film Thickness and Ellipsometry
Reflectance interference and polarization-sensitive response over a wide band. Wavelength accuracy and reproducibility determine thickness accuracy directly.
Overlay and Optical CD
Scatterometry requires a broad, well-calibrated spectrum and low stray light so that weak diffraction orders remain measurable.
Light-Source and Lithography Monitoring
Spectral balance and stability of broadband and laser-driven sources, increasingly below 200 nm, determine the reliability of every downstream measurement.
Display, LED and VCSEL Test
Fast visible measurement with repeatable luminance and color for OLED, mini-LED and micro-LED inspection, and high resolution for wafer-level VCSEL and laser characterization.
Contamination and Particle Detection
Trace-level identification in which the signal of interest occupies the last percent of the dynamic range.
Selection criteria
Specifications that matter in this application
Every spectrometer datasheet leads with wavelength range. In this application it is rarely the limiting specification. The following specifications are:
- Thermal stability, because a fab floor is not a temperature-controlled laboratory
- Stray light, because thin-film and scatterometry signals are small
- Dynamic range, because a broadband source is bright in the visible and weak in the UV and NIR at the same time
- Wavelength reproducibility across power cycles
- Trigger timing, buffering, and a form factor and interface suited to a tool rather than a bench
Tool Integration
Acquisition requirements inside a process tool
Inside a tool, the spectrometer has to acquire on a hardware event, hold data while the host is busy, and recover without a service call. Ethernet-ready configurations combine Gigabit Ethernet with onboard memory, ring-buffer and batch acquisition, near-zero trigger latency and a hardware reset line, so the equipment can treat the spectrometer as one of its own subsystems. Ethernet-ready spectrometers →
- Gigabit Ethernet for equipment-style control architectures and long cable runs
- Onboard memory that decouples exposure timing from host-transfer timing
- Ring-buffer acquisition for continuous capture and batch acquisition for gap-free sequences
- Near-zero trigger latency so each spectrum corresponds to a defined hardware event
- Hardware reset for recovery in an installed system
Below 200 nm
Deep-UV measurements with a nitrogen-purged optical path
Source monitoring, plasma emission and UV inspection increasingly require wavelengths that a standard UV-Vis bench cannot reach. The deep-UV SmartEngine configuration covers 155–410 nm with a nitrogen-purged optical path, because below 200 nm air absorption, contamination and stray light affect the measurement as much as the grating does. It is an application-specific option rather than a general replacement for UV spectrometers. Deep-UV SmartEngine →
Wide-Range Coverage
Staged detectors from the deep UV to 2500 nm
No single detector performs well from the deep UV to 2500 nm. Dual spectrometer systems, single-input dual-detector NIR and staged full-range architectures place more than one detector behind one optical input and one trigger, so silicon and InGaAs each cover the region where they perform best. Wide-range architectures →
Recommended platforms
Instruments suited to this application
These are typical starting points. Send the measurement details and an engineer will confirm the selection or recommend an alternative.
UV-Vis
SmartEngine UV-VNIR Spectrometer
Workhorse UV-VNIR platform with CCD and CMOS sensor options
UV-Vis
SilverBullet Compact OEM UV-Vis Spectrometer
Market-leading UV-Vis performance
High-Resolution
Magna High-Resolution Spectrometer
High Resolution Vis-NIR and NIR spectrometer
Also relevant: EagleEye UV-Vis-NIR Spectrometer, SideWinder NIR Spectrometer, Dual Spectrometer Systems (DS Series), HummingBird Compact OEM UV-Vis Spectrometer
Project process
From measurement definition to a frozen configuration
Define the measurement
Source, sample, geometry, and what the algorithm needs from the spectrum.
Select detector and bench
Silicon or InGaAs, cooled or uncooled, and the optical bench suited to the range.
Configure
Slit, grating, integration time, trigger mode and interface.
Validate
Representative sources, wafers, films or process conditions, on your tool or at Evolve.
Freeze the configuration
Configuration locked for pilot, OEM integration or production.
Scope
Scope of supply
A spectrometer does not qualify a process. Evolve Sensing supplies configurable measurement engines and the engineering to integrate them. Process qualification, recipe development and tool-level real-time guarantees belong to the system integrator and require application-specific validation. Near-zero trigger latency describes the spectrometer itself, not the networked response of the complete instrument.
FAQ
Frequently asked questions
- Can one supplier cover UV, visible and NIR semiconductor measurements?
- Yes. Evolve Sensing offers UV-Vis-NIR, TE-cooled, InGaAs NIR, high-resolution, OCT and dual-spectrometer platforms, plus deep-UV configurations, with staged full-range architectures available on request.
- Is the deep-UV SmartEngine a replacement for every UV spectrometer?
- No. It is an option for measurements that require coverage toward 155 nm. Above 200 nm the standard UV-Vis benches are usually the better choice, and the right selection depends on source, optics, purge requirements and calibration.
- Does Evolve support OEM tool integration?
- Yes. Compact form factors, programmable I/O, triggering, onboard buffering, Gigabit Ethernet, a documented SDK and configuration planning against the tool architecture are all available.
Next step
Discuss your application with an engineer
Send the wavelength range, the sample type and the accuracy required, and an Evolve Sensing applications engineer will recommend a configuration, typically within one business day.